title: WindowsDiskDriveNotOK
|
|
---
|
|
|
|
## Meaning
|
|
|
|
The physical drive `device_id` reports an operational status other than `OK`
|
|
for five minutes. The alert carries the status, such as `Pred Fail`, `Degraded`
|
|
or `Error`, in its `status` label. It needs the `diskdrive` collector, which
|
|
reads the status that the drive and its driver report through WMI. The
|
|
`Unknown` status does not raise the alert: some USB and virtual drives report
|
|
it permanently. Transient statuses such as `Starting` or `Stopping` raise it
|
|
only when they last longer than five minutes.
|
|
|
|
## Impact
|
|
|
|
`Pred Fail` is the drive's own prediction that it is about to fail. Any other
|
|
status means the drive is not fully working. Data on a single drive is at risk;
|
|
a drive in a mirror or parity set leaves the set without redundancy until it is
|
|
replaced.
|
|
|
|
## Diagnosis
|
|
|
|
1. Inspect `windows_diskdrive_status` for the host and check whether the
|
|
volumes on the drive still report normal latency with
|
|
`windows:logical_disk_read_latency:seconds` and
|
|
`windows:logical_disk_write_latency:seconds`.
|
|
2. On the host, read the drive and its reliability counters:
|
|
|
|
```powershell
|
|
Get-CimInstance Win32_DiskDrive | Select-Object DeviceID, Model, Status
|
|
Get-PhysicalDisk | Select-Object FriendlyName, HealthStatus, OperationalStatus
|
|
Get-PhysicalDisk | Get-StorageReliabilityCounter | Select-Object DeviceId, ReadErrorsTotal, WriteErrorsTotal, Temperature, Wear
|
|
```
|
|
|
|
3. Check the System event log for disk, storahci, stornvme or RAID controller
|
|
events. On a virtual machine, check the hypervisor and the datastore of the
|
|
virtual disk.
|
|
|
|
## Mitigation
|
|
|
|
Back up the data on the drive first. Replace a drive that predicts its failure
|
|
or reports errors through the hardware or virtualization team. For a drive in
|
|
a storage pool or RAID set, follow the vendor's replacement and rebuild
|
|
procedure and confirm the set is redundant again. The alert resolves when the
|
|
status returns to `OK`.
|