title: WindowsClockSourceLocal
|
|
---
|
|
|
|
## Meaning
|
|
|
|
Windows Time reports `Local CMOS Clock` or `NoSync` as the source of the system
|
|
clock for ten minutes. The alert carries the source in its `type` label. It
|
|
needs the `time` collector with its `clock_source` subcollector and covers
|
|
domain members too, whose source is `NT5DS` when they synchronize from the
|
|
domain hierarchy; the NTP source count of `WindowsClockNotSynchronising` does
|
|
not see those hosts. A host that is meant to be the free-running reference of
|
|
an isolated network reports the local clock by design; exclude it with
|
|
`alerts+: { WindowsClockSourceLocal: false }` on that configuration.
|
|
|
|
## Impact
|
|
|
|
The clock drifts without an external source. Clock errors break Kerberos
|
|
authentication beyond the five minute tolerance, TLS validation, scheduled
|
|
work, log correlation and distributed systems that depend on time order.
|
|
|
|
## Diagnosis
|
|
|
|
1. Inspect `windows_time_clock_sync_source` for the host, and
|
|
`windows_time_computed_time_offset_seconds` to see how far the clock has
|
|
already drifted.
|
|
2. On the host, check the configured and the effective source:
|
|
|
|
```powershell
|
|
w32tm /query /source
|
|
w32tm /query /status
|
|
w32tm /query /configuration
|
|
Get-Service W32Time
|
|
```
|
|
|
|
3. `Local CMOS Clock` after a reboot often means the Windows Time service
|
|
started before the network was up or the configured peers were unreachable.
|
|
`NoSync` means the time provider is configured not to synchronize.
|
|
4. For domain members, check that a domain controller is reachable and that
|
|
the PDC emulator synchronizes from an external source. For virtual machines,
|
|
check whether hypervisor time integration overrides the configured source.
|
|
A Hyper-V guest outside a domain that is kept in time by the integration
|
|
service reports `NoSync` while `w32tm /query /source` shows the
|
|
`VM IC Time Synchronization Provider`; that is by design, so turn the alert
|
|
off for such guests with `alerts+: { WindowsClockSourceLocal: false }` or
|
|
configure an NTP source in the guest.
|
|
|
|
## Mitigation
|
|
|
|
Configure the intended source and restart synchronization with
|
|
`w32tm /config /syncfromflags:domhier /update` on domain members or
|
|
`w32tm /config /manualpeerlist:"<servers>" /syncfromflags:manual /update` on
|
|
stand-alone hosts, then `w32tm /resync /rediscover`. Fix network access to the
|
|
peers over UDP port 123. Confirm the source changes to `NT5DS` or `NTP` and the
|
|
offset returns to normal; follow [WindowsClockSkewDetected](../windowsclockskewdetected/)
|
|
if it does not.
|