title: WindowsCollectorTimeout
---
## Meaning
The collector identified by the `collector` label has reported
`windows_exporter_collector_timeout == 1` for ten minutes. The collector did
not finish within the scrape timeout, or its call from an earlier scrape is
still running and later scrapes skip it until it returns.
## Impact
The metrics of this collector are missing or stale on every scrape that times
out, so dashboards show gaps and alerts on those metrics stop evaluating. A
collector that never returns can hold a scrape slot and delay the other
collectors of the host.
## Diagnosis
1. Find the collector and compare how long it usually takes:
```promql
windows_exporter_collector_timeout{job="windows_exporter"} == 1
windows_exporter_collector_duration_seconds{job="windows_exporter"}
```
2. Compare the duration with the scrape timeout of the job. The exporter
subtracts `--scrape.timeout-margin` from the `scrape_timeout` that
Prometheus sends.
3. Check the exporter log for the collector. WMI and Management Infrastructure
queries, the Task Scheduler and Windows Update are slow on hosts with many
objects or a busy WMI provider; the collector's documentation lists the
expensive options.
4. Check whether the host was under CPU, disk or memory pressure at the same
time, and whether a Windows service the collector depends on hangs, for
example `Winmgmt` for WMI-based collectors.
## Mitigation
Raise the `scrape_timeout` of the job within its `scrape_interval`, narrow the
collector with its include and exclude flags, or move the collector to a
separate job with a longer timeout. Restart a hanging provider service when the
log identifies it. Disable the collector on hosts where its data is not needed.
Confirm `windows_exporter_collector_timeout` returns to `0` and the collector's
metrics are published again.