- Removed HighPrecisionTemperature property and just mapped it to Temperature
- Converted decikelvin to Celsius - Added a loop to get the values from each zone - Added documentation for percent passive limit and throttle reasons
This commit is contained in:
@@ -16,10 +16,11 @@ None
|
||||
|
||||
Name | Description | Type | Labels
|
||||
-----|-------------|------|-------
|
||||
`wmi_thermalzone_high_precision_temperature` | _Not yet documented_ | gauge | None
|
||||
`wmi_thermalzone_percent_passive_limit` | _Not yet documented_ | gauge | None
|
||||
`wmi_thermalzone_temperature ` | _Not yet documented_ | gauge | None
|
||||
`wmi_thermalzone_throttle_reasons ` | _Not yet documented_ | gauge | None
|
||||
`wmi_thermalzone_percent_passive_limit` | % Passive Limit is the current limit this thermal zone is placing on the devices it controls. A limit of 100% indicates the devices are unconstrained. A limit of 0% indicates the devices are fully constrained. | gauge | None
|
||||
`wmi_thermalzone_temperature_celsius ` | Temperature of the thermal zone, in degrees Celsius. | gauge | None
|
||||
`wmi_thermalzone_throttle_reasons ` | Throttle Reasons indicate reasons why the thermal zone is limiting performance of the devices it controls. 0x0 – The zone is not throttled. 0x1 – The zone is throttled for thermal reasons. 0x2 – The zone is throttled to limit electrical current. | gauge | None
|
||||
|
||||
[`Throttle reasons` source](https://docs.microsoft.com/en-us/windows-hardware/design/device-experiences/examples--requirements-and-diagnostics)
|
||||
|
||||
### Example metric
|
||||