- Removed HighPrecisionTemperature property and just mapped it to Temperature

- Converted decikelvin to Celsius
- Added a loop to get the values from each zone
- Added documentation for percent passive limit and throttle reasons
This commit is contained in:
Stewart Thomson
2019-07-15 09:50:02 -04:00
parent 1a67ca54b6
commit 47656b16bd
2 changed files with 42 additions and 43 deletions
+37 -39
View File
@@ -12,38 +12,37 @@ func init() {
// A ThermalZoneCollector is a Prometheus collector for WMI Win32_PerfRawData_Counters_ThermalZoneInformation metrics
type ThermalZoneCollector struct {
HighPrecisionTemperature *prometheus.Desc
PercentPassiveLimit *prometheus.Desc
Temperature *prometheus.Desc
ThrottleReasons *prometheus.Desc
PercentPassiveLimit *prometheus.Desc
Temperature *prometheus.Desc
ThrottleReasons *prometheus.Desc
}
// NewThermalZoneCollector ...
func NewThermalZoneCollector() (Collector, error) {
const subsystem = "thermalzone"
return &ThermalZoneCollector{
HighPrecisionTemperature: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "high_precision_temperature"),
"(HighPrecisionTemperature)",
nil,
Temperature: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "temperature_celsius"),
"(Temperature)",
[]string{
"Name",
},
nil,
),
PercentPassiveLimit: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "percent_passive_limit"),
"(PercentPassiveLimit)",
nil,
nil,
),
Temperature: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "temperature"),
"(Temperature)",
nil,
[]string{
"Name",
},
nil,
),
ThrottleReasons: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "throttle_reasons"),
"(ThrottleReasons)",
nil,
[]string{
"Name",
},
nil,
),
}, nil
@@ -60,13 +59,12 @@ func (c *ThermalZoneCollector) Collect(ch chan<- prometheus.Metric) error {
}
// Win32_PerfRawData_Counters_ThermalZoneInformation docs:
// - <add link to documentation here>
// https://wutils.com/wmi/root/cimv2/win32_perfrawdata_counters_thermalzoneinformation/
type Win32_PerfRawData_Counters_ThermalZoneInformation struct {
Name string
HighPrecisionTemperature uint32
PercentPassiveLimit uint32
Temperature uint32
ThrottleReasons uint32
}
@@ -77,29 +75,29 @@ func (c *ThermalZoneCollector) collect(ch chan<- prometheus.Metric) (*prometheus
return nil, err
}
ch <- prometheus.MustNewConstMetric(
c.HighPrecisionTemperature,
prometheus.GaugeValue,
float64(dst[0].HighPrecisionTemperature),
)
for _, info := range dst {
//Divide by 10 and subtract 273.15 to convert decikelvin to celsius
ch <- prometheus.MustNewConstMetric(
c.Temperature,
prometheus.GaugeValue,
(float64(info.HighPrecisionTemperature)/10.0)-273.15,
info.Name,
)
ch <- prometheus.MustNewConstMetric(
c.PercentPassiveLimit,
prometheus.GaugeValue,
float64(dst[0].PercentPassiveLimit),
)
ch <- prometheus.MustNewConstMetric(
c.PercentPassiveLimit,
prometheus.GaugeValue,
float64(info.PercentPassiveLimit),
info.Name,
)
ch <- prometheus.MustNewConstMetric(
c.Temperature,
prometheus.GaugeValue,
float64(dst[0].Temperature),
)
ch <- prometheus.MustNewConstMetric(
c.ThrottleReasons,
prometheus.GaugeValue,
float64(dst[0].ThrottleReasons),
)
ch <- prometheus.MustNewConstMetric(
c.ThrottleReasons,
prometheus.GaugeValue,
float64(info.ThrottleReasons),
info.Name,
)
}
return nil, nil
}
+5 -4
View File
@@ -16,10 +16,11 @@ None
Name | Description | Type | Labels
-----|-------------|------|-------
`wmi_thermalzone_high_precision_temperature` | _Not yet documented_ | gauge | None
`wmi_thermalzone_percent_passive_limit` | _Not yet documented_ | gauge | None
`wmi_thermalzone_temperature ` | _Not yet documented_ | gauge | None
`wmi_thermalzone_throttle_reasons ` | _Not yet documented_ | gauge | None
`wmi_thermalzone_percent_passive_limit` | % Passive Limit is the current limit this thermal zone is placing on the devices it controls. A limit of 100% indicates the devices are unconstrained. A limit of 0% indicates the devices are fully constrained. | gauge | None
`wmi_thermalzone_temperature_celsius ` | Temperature of the thermal zone, in degrees Celsius. | gauge | None
`wmi_thermalzone_throttle_reasons ` | Throttle Reasons indicate reasons why the thermal zone is limiting performance of the devices it controls. 0x0 – The zone is not throttled. 0x1 – The zone is throttled for thermal reasons. 0x2 – The zone is throttled to limit electrical current. | gauge | None
[`Throttle reasons` source](https://docs.microsoft.com/en-us/windows-hardware/design/device-experiences/examples--requirements-and-diagnostics)
### Example metric
_This collector does not yet have explained examples, we would appreciate your help adding them!_