Files
windows_exporter/internal/collector/system/system.go

220 lines
6.1 KiB
Go

// SPDX-License-Identifier: Apache-2.0
//
// Copyright The Prometheus Authors
// Licensed under the Apache License, Version 2.0 (the "License");
// you may not use this file except in compliance with the License.
// You may obtain a copy of the License at
//
// http://www.apache.org/licenses/LICENSE-2.0
//
// Unless required by applicable law or agreed to in writing, software
// distributed under the License is distributed on an "AS IS" BASIS,
// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
// See the License for the specific language governing permissions and
// limitations under the License.
//go:build windows
package system
import (
"fmt"
"log/slog"
"time"
"github.com/alecthomas/kingpin/v2"
"github.com/prometheus-community/windows_exporter/internal/headers/kernel32"
"github.com/prometheus-community/windows_exporter/internal/mi"
"github.com/prometheus-community/windows_exporter/internal/pdh"
"github.com/prometheus-community/windows_exporter/internal/types"
"github.com/prometheus/client_golang/prometheus"
)
const Name = "system"
type Config struct{}
//nolint:gochecknoglobals
var ConfigDefaults = Config{}
// A Collector is a Prometheus Collector for WMI metrics.
type Collector struct {
config Config
bootTimeTimestamp float64
perfDataCollector *pdh.Collector
perfDataObject []perfDataCounterValues
contextSwitchesTotal *prometheus.Desc
exceptionDispatchesTotal *prometheus.Desc
processorQueueLength *prometheus.Desc
processes *prometheus.Desc
processesLimit *prometheus.Desc
systemCallsTotal *prometheus.Desc
// Deprecated: Use windows_system_boot_time_timestamp instead
bootTimeSeconds *prometheus.Desc
bootTime *prometheus.Desc
threads *prometheus.Desc
}
func New(config *Config) *Collector {
if config == nil {
config = &ConfigDefaults
}
c := &Collector{
config: *config,
}
return c
}
func NewWithFlags(_ *kingpin.Application) *Collector {
return &Collector{}
}
func (c *Collector) GetName() string {
return Name
}
func (c *Collector) Close() error {
c.perfDataCollector.Close()
return nil
}
func (c *Collector) Build(_ *slog.Logger, _ *mi.Session) error {
c.bootTime = prometheus.NewDesc(
prometheus.BuildFQName(types.Namespace, Name, "boot_time_timestamp"),
"Unix timestamp of system boot time",
nil,
nil,
)
c.bootTimeSeconds = prometheus.NewDesc(
prometheus.BuildFQName(types.Namespace, Name, "boot_time_timestamp_seconds"),
"Deprecated: Use windows_system_boot_time_timestamp instead",
nil,
nil,
)
c.contextSwitchesTotal = prometheus.NewDesc(
prometheus.BuildFQName(types.Namespace, Name, "context_switches_total"),
"Total number of context switches (WMI source: PerfOS_System.ContextSwitchesPersec)",
nil,
nil,
)
c.exceptionDispatchesTotal = prometheus.NewDesc(
prometheus.BuildFQName(types.Namespace, Name, "exception_dispatches_total"),
"Total number of exceptions dispatched (WMI source: PerfOS_System.ExceptionDispatchesPersec)",
nil,
nil,
)
c.processes = prometheus.NewDesc(
prometheus.BuildFQName(types.Namespace, Name, "processes"),
"Current number of processes (WMI source: PerfOS_System.Processes)",
nil,
nil,
)
c.processesLimit = prometheus.NewDesc(
prometheus.BuildFQName(types.Namespace, Name, "processes_limit"),
"Maximum number of processes.",
nil,
nil,
)
c.processorQueueLength = prometheus.NewDesc(
prometheus.BuildFQName(types.Namespace, Name, "processor_queue_length"),
"Length of processor queue (WMI source: PerfOS_System.ProcessorQueueLength)",
nil,
nil,
)
c.systemCallsTotal = prometheus.NewDesc(
prometheus.BuildFQName(types.Namespace, Name, "system_calls_total"),
"Total number of system calls (WMI source: PerfOS_System.SystemCallsPersec)",
nil,
nil,
)
c.threads = prometheus.NewDesc(
prometheus.BuildFQName(types.Namespace, Name, "threads"),
"Current number of threads (WMI source: PerfOS_System.Threads)",
nil,
nil,
)
c.bootTimeTimestamp = float64(uint64(time.Now().UnixMilli())-kernel32.GetTickCount64()) / 1000
var err error
c.perfDataCollector, err = pdh.NewCollector[perfDataCounterValues](pdh.CounterTypeRaw, "System", nil)
if err != nil {
return fmt.Errorf("failed to create System collector: %w", err)
}
return nil
}
// Collect sends the metric values for each metric
// to the provided prometheus Metric channel.
func (c *Collector) Collect(ch chan<- prometheus.Metric) error {
err := c.perfDataCollector.Collect(&c.perfDataObject)
if err != nil {
return fmt.Errorf("failed to collect System metrics: %w", err)
} else if len(c.perfDataObject) == 0 {
return fmt.Errorf("failed to collect System metrics: %w", types.ErrNoDataUnexpected)
}
ch <- prometheus.MustNewConstMetric(
c.contextSwitchesTotal,
prometheus.CounterValue,
c.perfDataObject[0].ContextSwitchesPerSec,
)
ch <- prometheus.MustNewConstMetric(
c.exceptionDispatchesTotal,
prometheus.CounterValue,
c.perfDataObject[0].ExceptionDispatchesPerSec,
)
ch <- prometheus.MustNewConstMetric(
c.processorQueueLength,
prometheus.GaugeValue,
c.perfDataObject[0].ProcessorQueueLength,
)
ch <- prometheus.MustNewConstMetric(
c.processes,
prometheus.GaugeValue,
c.perfDataObject[0].Processes,
)
ch <- prometheus.MustNewConstMetric(
c.systemCallsTotal,
prometheus.CounterValue,
c.perfDataObject[0].SystemCallsPerSec,
)
ch <- prometheus.MustNewConstMetric(
c.threads,
prometheus.GaugeValue,
c.perfDataObject[0].Threads,
)
ch <- prometheus.MustNewConstMetric(
c.bootTimeSeconds,
prometheus.GaugeValue,
c.bootTimeTimestamp,
)
ch <- prometheus.MustNewConstMetric(
c.bootTime,
prometheus.GaugeValue,
c.bootTimeTimestamp,
)
// Windows has no defined limit, and is based off available resources. This currently isn't calculated by WMI and is set to default value.
// https://techcommunity.microsoft.com/t5/windows-blog-archive/pushing-the-limits-of-windows-processes-and-threads/ba-p/723824
// https://docs.microsoft.com/en-us/windows/win32/cimwin32prov/win32-operatingsystem
ch <- prometheus.MustNewConstMetric(
c.processesLimit,
prometheus.GaugeValue,
float64(4294967295),
)
return nil
}