Files
windows_exporter/collector/thermalzone.go
2019-07-12 14:54:20 -04:00

106 lines
2.7 KiB
Go

package collector
import (
"github.com/StackExchange/wmi"
"github.com/prometheus/client_golang/prometheus"
"github.com/prometheus/common/log"
)
func init() {
Factories["thermalzone"] = NewThermalZoneCollector
}
// A ThermalZoneCollector is a Prometheus collector for WMI Win32_PerfRawData_Counters_ThermalZoneInformation metrics
type ThermalZoneCollector struct {
HighPrecisionTemperature *prometheus.Desc
PercentPassiveLimit *prometheus.Desc
Temperature *prometheus.Desc
ThrottleReasons *prometheus.Desc
}
// NewThermalZoneCollector ...
func NewThermalZoneCollector() (Collector, error) {
const subsystem = "thermalzone"
return &ThermalZoneCollector{
HighPrecisionTemperature: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "high_precision_temperature"),
"(HighPrecisionTemperature)",
nil,
nil,
),
PercentPassiveLimit: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "percent_passive_limit"),
"(PercentPassiveLimit)",
nil,
nil,
),
Temperature: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "temperature"),
"(Temperature)",
nil,
nil,
),
ThrottleReasons: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "throttle_reasons"),
"(ThrottleReasons)",
nil,
nil,
),
}, nil
}
// Collect sends the metric values for each metric
// to the provided prometheus Metric channel.
func (c *ThermalZoneCollector) Collect(ch chan<- prometheus.Metric) error {
if desc, err := c.collect(ch); err != nil {
log.Error("failed collecting thermalzone metrics:", desc, err)
return err
}
return nil
}
// Win32_PerfRawData_Counters_ThermalZoneInformation docs:
// - <add link to documentation here>
type Win32_PerfRawData_Counters_ThermalZoneInformation struct {
Name string
HighPrecisionTemperature uint32
PercentPassiveLimit uint32
Temperature uint32
ThrottleReasons uint32
}
func (c *ThermalZoneCollector) collect(ch chan<- prometheus.Metric) (*prometheus.Desc, error) {
var dst []Win32_PerfRawData_Counters_ThermalZoneInformation
q := queryAll(&dst)
if err := wmi.Query(q, &dst); err != nil {
return nil, err
}
ch <- prometheus.MustNewConstMetric(
c.HighPrecisionTemperature,
prometheus.GaugeValue,
float64(dst[0].HighPrecisionTemperature),
)
ch <- prometheus.MustNewConstMetric(
c.PercentPassiveLimit,
prometheus.GaugeValue,
float64(dst[0].PercentPassiveLimit),
)
ch <- prometheus.MustNewConstMetric(
c.Temperature,
prometheus.GaugeValue,
float64(dst[0].Temperature),
)
ch <- prometheus.MustNewConstMetric(
c.ThrottleReasons,
prometheus.GaugeValue,
float64(dst[0].ThrottleReasons),
)
return nil, nil
}