# service collector - `EnumServicesStatusEx` returns state and PID of all services in one call. The configuration needs `OpenService`, `QueryServiceConfig` and `CloseServiceHandle` per service, which costs CPU in services.exe as well, so it is cached in [`config_cache.go`](config_cache.go). Never cache state or PID. - `NotifyServiceStatusChange` does not report configuration changes. The cache watches `HKLM\SYSTEM\CurrentControlSet\Services` with `RegNotifyChangeKeyValue` instead. Arm it with `REG_NOTIFY_THREAD_AGNOSTIC`: without it the registration ends when the arming OS thread exits, and Go goroutines are not bound to one. - The delayed auto-start flag and the triggers are queried with `QueryServiceConfig2` on the same handle and cached with the configuration. The SCM ignores the delayed flag unless the start type is auto, so it is only queried for auto-start services. `x/sys/windows` has no `SERVICE_TRIGGER_INFO`; the mirror in `service.go` only reads `cTriggers`. - The delayed flag is the `DelayedAutostart` value of the service key, so a change updates the key's last write time. Triggers are stored in the `TriggerInfo` subkey. Adding the first trigger creates it, which updates the last write time of the service key (`TestCollectorPicksUpConfigChanges` checks this). That a later trigger change made with `sc triggerinfo` also does is assumed, not verified: the SCM is believed to rewrite the whole `TriggerInfo` subkey. If it only changes deeper keys, the cache picks the change up after at most `configCacheMaxAge`. - The subtree notification fires every few seconds on a normal machine (W32Time, Tcpip, VSS, driver `Enum` keys, Hyper-V). Treat it as a hint only and compare the last write time of each service's own key, which changes only for its own values and direct subkeys. - Registry write times have a resolution of one clock tick, so two writes in the same tick leave the time unchanged. Only cache a configuration once its key is older than `configCacheMinKeyAge`, and never cache an unavailable one (for example a missing MUI display name), which can change without a write. - The cache tests use a temporary key below `HKEY_CURRENT_USER`, so they run without elevation. Registry write times have a coarse resolution; sleep before a write that must get a newer time. - `TestCollectorPicksUpConfigChanges` creates a real service and changes it through the SCM. It needs an elevated process: it skips locally without one and fails in CI, where `service` is in `WINDOWS_EXPORTER_TEST_COLLECTORS`.