//go:build windows package cpu_info import ( "errors" "strconv" "strings" "github.com/alecthomas/kingpin/v2" "github.com/go-kit/log" "github.com/go-kit/log/level" "github.com/prometheus-community/windows_exporter/pkg/types" "github.com/prometheus-community/windows_exporter/pkg/wmi" "github.com/prometheus/client_golang/prometheus" ) const ( Name = "cpu_info" // If you are adding additional labels to the metric, make sure that they get added in here as well. See below for explanation. win32ProcessorQuery = "SELECT Architecture, DeviceId, Description, Family, L2CacheSize, L3CacheSize, Name FROM Win32_Processor" ) type Config struct{} var ConfigDefaults = Config{} // A Collector is a Prometheus Collector for a few WMI metrics in Win32_Processor type Collector struct { logger log.Logger cpuInfo *prometheus.Desc } func New(logger log.Logger, _ *Config) *Collector { c := &Collector{} c.SetLogger(logger) return c } func NewWithFlags(_ *kingpin.Application) *Collector { return &Collector{} } func (c *Collector) GetName() string { return Name } func (c *Collector) SetLogger(logger log.Logger) { c.logger = log.With(logger, "collector", Name) } func (c *Collector) GetPerfCounter() ([]string, error) { return []string{}, nil } func (c *Collector) Close() error { return nil } func (c *Collector) Build() error { c.cpuInfo = prometheus.NewDesc( prometheus.BuildFQName(types.Namespace, "", Name), "Labelled CPU information as provided provided by Win32_Processor", []string{ "architecture", "device_id", "description", "family", "l2_cache_size", "l3_cache_size", "name", }, nil, ) return nil } type win32_Processor struct { Architecture uint32 DeviceID string Description string Family uint16 L2CacheSize uint32 L3CacheSize uint32 Name string } // Collect sends the metric values for each metric // to the provided prometheus Metric channel. func (c *Collector) Collect(_ *types.ScrapeContext, ch chan<- prometheus.Metric) error { if err := c.collect(ch); err != nil { _ = level.Error(c.logger).Log("msg", "failed collecting cpu_info metrics", "err", err) return err } return nil } func (c *Collector) collect(ch chan<- prometheus.Metric) error { var dst []win32_Processor // We use a static query here because the provided methods in wmi.go all issue a SELECT *; // This results in the time-consuming LoadPercentage field being read which seems to measure each CPU // serially over a 1 second interval, so the scrape time is at least 1s * num_sockets if err := wmi.Query(win32ProcessorQuery, &dst); err != nil { return err } if len(dst) == 0 { return errors.New("WMI query returned empty result set") } // Some CPUs end up exposing trailing spaces for certain strings, so clean them up for _, processor := range dst { ch <- prometheus.MustNewConstMetric( c.cpuInfo, prometheus.GaugeValue, 1.0, strconv.Itoa(int(processor.Architecture)), strings.TrimRight(processor.DeviceID, " "), strings.TrimRight(processor.Description, " "), strconv.Itoa(int(processor.Family)), strconv.Itoa(int(processor.L2CacheSize)), strconv.Itoa(int(processor.L3CacheSize)), strings.TrimRight(processor.Name, " "), ) } return nil }