title: WindowsDiskDriveNotOK
|
||||
---
|
||||
|
||||
## Meaning
|
||||
|
||||
The physical drive `device_id` reports an operational status other than `OK`
|
||||
for five minutes. The alert carries the status, such as `Pred Fail`, `Degraded`
|
||||
or `Error`, in its `status` label. It needs the `diskdrive` collector, which
|
||||
reads the status that the drive and its driver report through WMI. The
|
||||
`Unknown` status does not raise the alert: some USB and virtual drives report
|
||||
it permanently. Transient statuses such as `Starting` or `Stopping` raise it
|
||||
only when they last longer than five minutes.
|
||||
|
||||
## Impact
|
||||
|
||||
`Pred Fail` is the drive's own prediction that it is about to fail. Any other
|
||||
status means the drive is not fully working. Data on a single drive is at risk;
|
||||
a drive in a mirror or parity set leaves the set without redundancy until it is
|
||||
replaced.
|
||||
|
||||
## Diagnosis
|
||||
|
||||
1. Inspect `windows_diskdrive_status` for the host and check whether the
|
||||
volumes on the drive still report normal latency with
|
||||
`windows:logical_disk_read_latency:seconds` and
|
||||
`windows:logical_disk_write_latency:seconds`.
|
||||
2. On the host, read the drive and its reliability counters:
|
||||
|
||||
```powershell
|
||||
Get-CimInstance Win32_DiskDrive | Select-Object DeviceID, Model, Status
|
||||
Get-PhysicalDisk | Select-Object FriendlyName, HealthStatus, OperationalStatus
|
||||
Get-PhysicalDisk | Get-StorageReliabilityCounter | Select-Object DeviceId, ReadErrorsTotal, WriteErrorsTotal, Temperature, Wear
|
||||
```
|
||||
|
||||
3. Check the System event log for disk, storahci, stornvme or RAID controller
|
||||
events. On a virtual machine, check the hypervisor and the datastore of the
|
||||
virtual disk.
|
||||
|
||||
## Mitigation
|
||||
|
||||
Back up the data on the drive first. Replace a drive that predicts its failure
|
||||
or reports errors through the hardware or virtualization team. For a drive in
|
||||
a storage pool or RAID set, follow the vendor's replacement and rebuild
|
||||
procedure and confirm the set is redundant again. The alert resolves when the
|
||||
status returns to `OK`.
|
||||