title: WindowsClockSourceLocal
|
||||
---
|
||||
|
||||
## Meaning
|
||||
|
||||
Windows Time reports `Local CMOS Clock` or `NoSync` as the source of the system
|
||||
clock for ten minutes. The alert carries the source in its `type` label. It
|
||||
needs the `time` collector with its `clock_source` subcollector and covers
|
||||
domain members too, whose source is `NT5DS` when they synchronize from the
|
||||
domain hierarchy; the NTP source count of `WindowsClockNotSynchronising` does
|
||||
not see those hosts. A host that is meant to be the free-running reference of
|
||||
an isolated network reports the local clock by design; exclude it with
|
||||
`alerts+: { WindowsClockSourceLocal: false }` on that configuration.
|
||||
|
||||
## Impact
|
||||
|
||||
The clock drifts without an external source. Clock errors break Kerberos
|
||||
authentication beyond the five minute tolerance, TLS validation, scheduled
|
||||
work, log correlation and distributed systems that depend on time order.
|
||||
|
||||
## Diagnosis
|
||||
|
||||
1. Inspect `windows_time_clock_sync_source` for the host, and
|
||||
`windows_time_computed_time_offset_seconds` to see how far the clock has
|
||||
already drifted.
|
||||
2. On the host, check the configured and the effective source:
|
||||
|
||||
```powershell
|
||||
w32tm /query /source
|
||||
w32tm /query /status
|
||||
w32tm /query /configuration
|
||||
Get-Service W32Time
|
||||
```
|
||||
|
||||
3. `Local CMOS Clock` after a reboot often means the Windows Time service
|
||||
started before the network was up or the configured peers were unreachable.
|
||||
`NoSync` means the time provider is configured not to synchronize.
|
||||
4. For domain members, check that a domain controller is reachable and that
|
||||
the PDC emulator synchronizes from an external source. For virtual machines,
|
||||
check whether hypervisor time integration overrides the configured source.
|
||||
A Hyper-V guest outside a domain that is kept in time by the integration
|
||||
service reports `NoSync` while `w32tm /query /source` shows the
|
||||
`VM IC Time Synchronization Provider`; that is by design, so turn the alert
|
||||
off for such guests with `alerts+: { WindowsClockSourceLocal: false }` or
|
||||
configure an NTP source in the guest.
|
||||
|
||||
## Mitigation
|
||||
|
||||
Configure the intended source and restart synchronization with
|
||||
`w32tm /config /syncfromflags:domhier /update` on domain members or
|
||||
`w32tm /config /manualpeerlist:"<servers>" /syncfromflags:manual /update` on
|
||||
stand-alone hosts, then `w32tm /resync /rediscover`. Fix network access to the
|
||||
peers over UDP port 123. Confirm the source changes to `NT5DS` or `NTP` and the
|
||||
offset returns to normal; follow [WindowsClockSkewDetected](../windowsclockskewdetected/)
|
||||
if it does not.
|
||||
Reference in New Issue