Reliability and worker maintenance

Circuit breaker

reliability.enabled activates a per-worker circuit breaker. Consecutive transport/backend failures increment the worker failure counter. At failure_threshold the circuit enters open for open_duration. After that period the next eligible request acts as the half-open probe; success closes the circuit, failure reopens it.

"reliability": {
  "enabled": true,
  "failure_threshold": 3,
  "open_duration": "30s",
  "retry_attempts": 2,
  "retry_backoff": "50ms"
}

Retries are deliberately conservative: only transport failures before any upstream response is committed to the client are retried. A backend HTTP 5xx contributes to the circuit breaker but is not replayed once its headers/body have begun.

Worker maintenance

The admin Worker page exposes:

  • active: accepts new inference jobs;
  • draining: no new inference jobs, existing jobs continue;
  • disabled: no new inference jobs until explicitly enabled.

Drain/disable state is persisted in <data_dir>/worker-state.json. Circuit state is intentionally transient and can be manually reset from the Worker page.