Files
netbird/client/internal/auth
Zoltan Papp 53bbc2d551 session: clear stale SSO deadline on teardown and after expiry
The session deadline lived in two sinks kept in sync by hand:
ApplySessionDeadline wrote both the (engine-scoped) sessionwatch.Watcher
and the (server-scoped) peer.Status recorder. The clear paths only
touched the watcher, so the recorder — which is what the Status RPC /
SubscribeStatus snapshot the UI reads from — kept reporting a deadline
that had gone stale, surfacing as a frozen "expires in …" countdown.

Two cases were leaking:
- Profile switch / Down: the watcher is recreated per engine but the
  recorder outlives it, so a switch to a profile whose server sends no
  deadline left the previous profile's value in place.
- In-place expiry: the watcher arms warning timers at T-WarningLead and
  T-FinalWarningLead but nothing at the deadline itself, so once the
  moment passed the recorder kept the now-past value indefinitely.

Make the watcher the single writer of the recorder deadline (Update /
clearLocked / Close all route through SetSessionExpiresAt) so teardown
clears it, and guard GetSessionExpiresAt to report a past deadline as
none so in-place expiry stops painting a stale countdown.
2026-05-26 23:15:03 +02:00
..
2026-05-20 16:43:14 +02:00
2026-05-20 16:43:14 +02:00
2026-05-20 16:43:14 +02:00