With the update-settings kill switch on, `netbird up --enable-rosenpass` connected and said almost nothing: SetConfig refused the change, the CLI downgraded that to a warning, and Login carries no rosenpass field to apply, so the flag was silently dropped. The setting stayed disabled, which is the point of the switch, but the caller was never told their request had been ignored. The refusal now travels as codes.FailedPrecondition instead of codes.Unavailable, and the CLI fails on it. Unavailable means "the daemon cannot serve this call", which is why the CLI downgraded it and why client/ui/services reads it as an unreachable daemon — both wrong for a daemon that answered and refused. FailedPrecondition also matches what the MDM gate already returns for a managed field, so both refusals are now one class of error, and it is added to the login backoff's early-exit codes so a refused login stops instead of retrying for 30s. This does not put the container back in the deadlock: with the value-aware gate, a client restating its own configuration is not refused at all, so nothing reaches this path unless a real change was asked for.